Monarch ACT-3X Panel Tachometer

$441.00

This item is built to order, and lead times vary based on configuration.

The ACT-3X Panel Tachometer/Totalizer/Ratemeter is a powerful NIST calibrated, fully programmable tachometer and totalizer. It accepts inputs from all Monarch speed sensors or from any standard TTL generating device. The unit operates from 120/240 Vac input power or from 12 or 24 Vdc input power (optional).

Input Power *

Sensor Power *

Analog Output *

Communications *

Alarm Relay Outputs *

Bentley Nevada Modification *

Order total:

The ACT-3X Panel Tachometer is an extremely versatile instrument. The user has complete control of the unit configuration. Power may be either 115 – 230 Vac (50/60 Hz), or optionally, 12 Vdc or 24 Vdc. Input signals are accepted (on Channel 1) from optical, proximity, magnetic, infrared or laser sensors, or direct TTL or external AC sources. A second auxiliary input (Channel 2) may be used for instrument control and remote resetting. There are several remote communication options – RS232, USB or Ethernet and the optional remote software can be used to program the unit or display data locally. The unit is suitable for panel mounting or bench top use, with convenient screw terminal connections on the rear panel of the instrument.

Set up for single-channel monitoring. Programmable scale factor with menu selection for multiple pulses per revolution, linear rates, single event trip speeds (using auxiliary input), and rate of change in RPM. A TTL pulse repeater output is standard. Recommended sensors with PN -W (= tinned leads), ROS-W, ROS-HT-W-25, P5-11, PS-12, M-190W, IRS-W, ROLS-W, RLS-W, SLS-115/230, CSLS, and GE-200HP Gas Engine Sensor (with amplifier).

Features

  • 1/8 DIN sized
  • 5-digit LED display
  • 5 to 999,990 RPM range
  • Universal sensor inputs
  • NIST Traceable Certificate included
  • User-configurable with front panel pushbuttons or free downloadable PM Remote Software
  • View real-time data on PC*
  • Record data in.CSV format in real time*
  • Universal ac power 100-240 Vac, 50/60 Hz or optional 12 or 24 Vdc power
  • Standard pulse repeater output
  • Single event capture from start-stop pulses, in units such as MPH, CM/sec, etc. using two sensors – for the linear rate of travel on the second input channel
  • Optional 4-20 mA or 0-5 Vdc scalable output
  • Optional Ethernet or USB communications
  • Optional alarm relay outputs

Specifications

*Specifications are subject to change without notice.

Specification Value
Speed Range 5-999,999 RPM (speeds below 5 RPM possible with multiple pulses per revolution)
Input Frequency Range 0.083 Hz to 250 kHz
Totalizer/Counter Display Range: 0.001 to 99,999 100,000 – 999,990 (only top 5 digits are shown — x10) Maximum # of counts of 16,777,216 even with a 0.001 scale
Input Configuration and Voltage Range Universal inputs: 1 to 9,999 pulses per revolution Front panel pushbutton programmable TTL input and 1.1 V to 50 Vac signals Opt: -1 to -50 Vdc
Accuracy +/-0.001% of reading or +/-1 displayed resolution (Standard Gate) +/-0.01% of reading or +/-1 displayed resolution (Fast Gate)
Resolution – Fixed Range Mode 1 RPM (5 to 99,999 RPM), 10 RPM (100,000 to 999,990 RPM)
Resolution – Auto Range Mode Up to 0.001 RPM
Display 5 digits, 0.56 inch high red seven segment LED
Display Update Menu selectable between: 0.5 second above 120 RPM, 1 Second above 60 RPM, 1.5 Second above 40 RPM
Max Measurement Rate Up to 100 times per second (Standard Gate) or up to 1000 (Fast Gate) Dependent on input frequency; Input must be > measurement rate
Scaling Mode – Scaling Computation Programmable scaling 0.0001 to 99,999; Front panel pushbutton programmable
Decimal Point User Selectable (0-3 decimal places max); Front panel pushbutton programmable
Memory Maximum/minimum recall from front panel pushbuttons
Dimensions 1/8 DIN by 3.94″ [100 mm] deep Panel cutout: 1.74″ H x 3/58″ W [44 mm x 91 mm]
Input Power Standard 100 – 240 Vac (50/60 Hz) 8 VA or Optional 12 Vdc or 24 Vdc isolated 6 W
Recommended Monarch Sensors Optical, Laser, Proximity, Magnetic, Infrared, HP Inductive – see product manual for details
Sensor Power Output 12 Vdc @ 60 mA standard, or optional 5 Vdc @ 60 mA or 24 Vdc @ 30 mA to sensor
Pulse Repeater Output TTL 0 to 5 V TTL compatible, one pulse out for each pulse in Menu selectable polarity
Serial Interface Options Bidirectional RS232C, USB or Ethernet Interface
Alarm Capability Two alarm setpoints: High or Low Alarm Limits and Latching or Non-latching Front panel pushbutton or remotely programmable Hysteresis and low limit lockout are programmable Relays can be set as failsafe
Analog Output† Voltage (AO): 0 to 5 Vdc, 5 mA max load, Isolated or Non-isolated or Current Source (IO): 4 to 20 mA (500Ω max load with internal 12 V Compliance Voltage), Isolated or Non-isolated (1-5V with 250Ω load resistor) 15-bit resolution; Front panel pushbutton programmable for full scale and offset RPM ranges
Alarm Outputs Form C relay contacts, rated 1A at 115 Vac or 230 Vac
Remote Programming Unit can be remotely programmed using Serial Interface (3.5 mm phone plug Serial Interface requires USB Programming Cable and PM Remote Software)
Weight 3 lbs

Downloads

Software

 

Monarch ACT-3X Panel Mount Tachometer-Totalizer
Monarch ACT-3X Panel Tachometer